A Declaration of Performance (DoP) is usually two pages, and most readers look at one line: the fire class. The fields that decide whether the product fits a specification are elsewhere on the page. They say which product the declaration covers, for which use, under which standard, which values were declared and which were not, and who checked them.
This guide reads the DoP field by field, using two real declarations for ceiling products: Troldtekt's DoP No. 01 for its cement-bonded wood wool panels and Rockfon's DoP-RFN-0140-041-4 for ROCKFON Blanka stone wool ceiling tiles. It is written for the specifier or buyer who has to decide whether the declared performance supports the clause the product is going into.
In short
- The DoP is the manufacturer's legal statement of performance. Regulation (EU) 305/2011, Article 4(3): by drawing it up the manufacturer "shall assume responsibility" for the declared performance.
- Read the intended use and the harmonised standard first. A value declared for one use under one standard does not carry to another.
- "NPD" means no performance determined. It is not a zero and not a pass.
- The level of third-party checking (the AVCP system) can differ by characteristic within one DoP.
- DoPs have versions. Three copies of Troldtekt's DoP No. 01 online give three thermal conductivity values and two notified bodies; the August 2026 version is the newest.
- The EU's new regulation, (EU) 2024/3110, replaces the DoP with a declaration of performance and conformity, family by family.
Terms Used Here
- DoP
- Declaration of Performance: the manufacturer's legal statement of performance under Regulation (EU) 305/2011.
- NPD
- No performance determined. Not a zero and not a pass.
- AVCP
- Assessment and verification of constancy of performance: how much third-party involvement sits behind a declared value. Five systems; under System 4 there are no tasks for the notified body.
- Notified body
- Named in point 6a. Its number should match the CE marking; for UKCA, a UK approved body such as BSI (0086).
- DoPC
- Declaration of performance and conformity: the replacement under Regulation (EU) 2024/3110, family by family.
The Model: Eight Points
Article 6 of Regulation (EU) 305/2011 sets what a DoP must contain, and Annex III gives the model. Delegated Regulation (EU) 574/2014 replaced that model with eight points: 1, unique identification code of the product-type; 2, intended use; 3, manufacturer; 4, authorised representative; 5, system of AVCP (assessment and verification of constancy of performance); 6a, harmonised standard and notified body, or 6b, European Assessment Document, European Technical Assessment and Technical Assessment Body; 7, declared performance; 8, appropriate or specific technical documentation. The delegated regulation lets manufacturers change the layout, combine points and omit those that do not apply, so not every DoP looks the same. The two below are laid out differently but carry the same information.
The Eight-Point Model, Delegated Regulation (EU) 574/2014
- 1Unique identification code of the product-typeA
- 2Intended useA
- 3Manufacturer
- 4Authorised representative
- 5System of AVCPB
- 6aHarmonised standard and notified bodyC
- 6bEuropean Assessment Document, European Technical Assessment and Technical Assessment Body
- 7Declared performanceD
- 8Appropriate or specific technical documentation
Point 1 and 2
Start with what the declaration covers, then read the intended use. A value declared for one use under one standard does not carry to another.
Read the fieldPoint 5
The AVCP system: how much third-party involvement sits behind a declared value. It can differ by characteristic within one DoP.
Read the fieldPoint 7
"NPD" means no performance determined. It is not a zero and not a pass. Read the conditions attached to each value.
Read the field
The Two DoPs, Side by Side
| DoP field | Troldtekt DoP No. 01, August 2026 (S5) | Rockfon DoP-RFN-0140-041-4 (S9) | What to check |
|---|---|---|---|
| Product identification | Troldtekt panels in extreme fine, ultrafine and fine structure in white cement, FUTURECEM and LEC, unpainted and painted | ROCKFON Blanka | The product, finish and edge you will order are named |
| Intended use | Indoor ceiling and wall cladding, direct installation (EN 13168) or suspended ceiling panels (EN 13964) | Suspended ceiling membrane for internal use | Your application is the declared use |
| Harmonised standard | DS/EN 13168:2012+A1:2015 and DS/EN 13964:2014 | EN 13964:2014 | Standard and date; two standards means two sets of declared values |
| AVCP system | System 1 | System 1 for reaction to fire; 3 for safety in use and dangerous substances; 4 for other parameters | Which characteristics a third party checked |
| Notified body | Technische Universität München HFM, No. 0797 | EU: NB 0749 (BCCA) for System 1; NB 1235 for System 3. UK: BSI (0086) | Number matches the CE or UKCA marking |
| Reaction to fire | B-s1,d0 | A1 | Class, and in the classification report the mounting conditions |
| Sound absorption | NPD | αw 1,00 (edges A and E) and 0,95 (other edges), construction depth 200 mm | Whether the acoustic value you rely on is declared, and for which mounting |
| Thermal conductivity | 0.083 W/mK | 0,040 W/mK (d ≥ 30 mm) | Rarely decisive for a ceiling, but shows thickness conditions |
| Formaldehyde | E1 | E1 | Class declared |
| Durability | Class D | C | Exposure class against your room conditions |
| Signed | Tranbjerg, 2026.08.19 | Hedehusene, 2022-11-07 | The version you are relying on |
All values manufacturer-stated, copied from the DoPs opened on 9 October 2026. Links in Sources. Full product records: Troldtekt acoustic product profile and Rockfon Blanka product profile.
Field 1: Product-Type and Intended Use
Start with what the declaration covers. Troldtekt's DoP No. 01 covers a family of finishes and structures under one declaration. Rockfon's covers one named product, ROCKFON Blanka. If the product on the quote has a different name, edge or facing from the one in point 1, ask which DoP covers it.
Then read the intended use. Troldtekt declares two uses, each tied to its own standard: direct fixing under EN 13168 and suspended ceilings under EN 13964. If your design fixes the panels directly to a wall, the EN 13168 block is the one that applies.
Field 5: The AVCP System
The AVCP system says how much third-party involvement sits behind a declared value. Annex V of Regulation (EU) 305/2011 sets five systems. Under System 1, a notified product certification body determines the product-type, inspects the plant and keeps factory production control under surveillance. Under System 3, a notified testing laboratory determines the product-type and the manufacturer runs factory production control. Under System 4 the manufacturer does both, with "no tasks for the notified body".
In the Rockfon DoP the system differs by characteristic: System 1 for reaction to fire, 3 for formaldehyde and flexural tensile strength, 4 for sound absorption and the remaining characteristics. Troldtekt's DoP states System 1. Read each declared value with its system beside it.
Field 7: Declared Performance, and What NPD Means
Article 6(3)(f) requires the letters "NPD" for listed characteristics where no performance is declared. Troldtekt's DoP lists sound absorption under EN 13964 and declares it NPD. Rockfon's declares a weighted sound absorption coefficient of 1,00 for edges A and E at a 200 mm construction depth.
That does not mean one product absorbs sound and the other does not. Troldtekt publishes absorption test values in a separate document, and our comparison of acoustic wall and ceiling panels sets those figures out. It means the two figures have different standing. Article 4(2) of Regulation (EU) 305/2011 provides that information about performance on an essential characteristic may be provided only if it is in the DoP, except where no DoP has been drawn up. A figure that sits in a brochure against an NPD in the DoP is a manufacturer statement outside the declaration. If your specification clause depends on αw, ask the manufacturer to confirm the value in writing, for your mounting, with the test report.
Read the conditions too. Rockfon's αw is declared for a 200 mm construction depth. A different plenum is a different construction.
Versions: The Same DoP Number, Different Values
Three copies of Troldtekt's DoP No. 01 were found online on 9 October 2026. The table above reads the newest, published on troldtekt.com as "AUGUST 2026 EN V01" and signed 2026.08.19: 0.083 W/mK, notified body 0797 (S5). EcoGaboon treats it as the current declaration. The other two are older copies signed in 2014, shown here as an illustration of what goes wrong when a DoP is taken from the wrong place, not as current data:
| Copy | Where found | Standards cited | Thermal conductivity | Notified body | Signature date |
|---|---|---|---|---|---|
| Newest (August 2026) | troldtekt.com | DS/EN 13168:2012+A1:2015; DS/EN 13964:2014 | 0.083 W/mK | 0797 (TU München HFM) | 2026.08.19 |
| Older copy | A second Troldtekt server (cms.troldtekt.dk) | DS/EN 13168:2012+A1:2015; DS/EN 13964:2014 | 0.081 W/mK | 0615 (Bureau Veritas) | 10/09 2014 |
| Older copy | Third-party specification library | DS/EN 13168:2008; EN 13964:2004/A1:2006 | 0.076 W/mK | 0615 (Bureau Veritas) | 10/09 2014 |
Thermal conductivity in three copies of Troldtekt DoP No. 01, W/mK
- Newest, August 2026troldtekt.com0.083
- Older copy, 2014cms.troldtekt.dk0.081
- Older copy, 2014Third-party library0.076
The older copies also name a different product range ("Troldtekt and Troldtekt agro panels"). Troldtekt's February 2026 data sheet still prints the 0615 certificate numbers (S8), so the data sheet and the current DoP name different notified bodies. Ask Troldtekt to confirm that the 2014 copies are withdrawn and which certificates are current. That is a question for the manufacturer, not a reason to reject the product.
The lesson is procedural. Take the DoP from the manufacturer's current product page or ask for it directly, record the version line, the standard edition and the notified body, and file the copy you relied on. Manufacturers must keep DoPs for 10 years after placing the product on the market (Article 11(2)); your file should hold the version that applied when you specified.
EU and UK Declarations in One File
Rockfon's file carries the EU declaration and a UK declaration. The UK page names BSI (0086) as the UK approved body and certificate BSI CPR 762605, and states it is issued under Regulation (EU) No 305/2011 "as it has effect in the United Kingdom". In Great Britain, gov.uk states the CE mark "will continue to be available" for construction products and the UKCA mark can also be used. Check that the declaration you file matches the marking on the product delivered.
What Changes Under Regulation (EU) 2024/3110
The new Construction Products Regulation applies from 8 January 2026 (Article 96). It replaces the DoP with a "declaration of performance and conformity" drawn up on the model in its Annex V (Article 15(1)). That declaration must include environmental characteristics listed in Annex II, phased in: climate change indicators from 8 January 2026, a second group from 9 January 2030 and a third from 9 January 2032 (Article 15(3)).
The obligations reach a product family only from one year after the implementing act for that family (Article 95(9)), and Article 94 keeps Annex III of Regulation (EU) 305/2011 in force until 8 January 2040 for products under the standards cited under the old regulation. For the ceiling products above, the DoPs opened today are both in the 305/2011 format. When a declaration of performance and conformity arrives, read it in the same order: identity, use, specification, system, declared values, NPD.
Last checked: 9 October 2026. This is product information, not legal advice.
What the DoP Does Not Tell You
- Whether a brochure or data sheet figure has the same standing. Against an NPD in the DoP, it is a manufacturer statement outside the declaration.
- The mounting behind the fire class. That sits in the classification report.
- Whether a value holds for another use, standard, thickness, edge or construction depth.
- Whether your copy is the current version. DoPs have versions under the same number.
Ten Checks Before the DoP Goes in the File
- The product name, finish and edge on the quote appear in point 1.
- Your application is the declared intended use.
- The harmonised standard (or EAD and ETA) is named and dated.
- The notified or approved body number matches the CE or UKCA marking.
- Each value you rely on is declared, not NPD.
- You have noted the AVCP system behind each value you rely on.
- Conditions attached to values (thickness, construction depth, edge) match your design.
- The fire class is backed by a classification report whose mounting matches your build-up.
- The copy came from the manufacturer, and you have recorded its date and standard edition.
- Values in the datasheet that are not in the DoP are filed as manufacturer statements.
For the wider pack that sits around the DoP, see the 14 documents to request. For the environmental declaration, see how to read an EPD. For DoP values on insulation boards, see wood fibre, mineral wool or PIR boards, and the wood fibre insulation material page.
Materials in This Guide
See the Declared Values on a Product Profile
Every EcoGaboon product profile shows the DoP number, the version date, the intended use and each declared value, with NPD entries left visible and a link to the manufacturer's own copy.
The basic listing is free. Manufacturers send the current DoP with the product data.
Sources
Checked 9 October 2026. Each reference in the text (S1 to S9) links here.