EcoCocon Straw Panel
EcoCocon · Timber frame with pressed straw
A load-bearing twin-stud timber frame panel filled with pressed straw at a homogeneous density, made to measure for each project (S1). Panels are assembled into walls and finished with further layers (for example a breather membrane, wood fibre board and clay plaster) to reach the required fire, thermal and acoustic performance (S1).
Where It Is Used
As stated (S1):
- Load-bearing external walls in low-rise residential and non-residential buildings.
- Façade infill or wrapping for skeleton-frame structures in mid-rise and high-rise buildings, including renovation wrapping.
- Load-bearing partition walls.
Stated restrictions and conditions (S1, S2, S6):
- Not for areas with permafrost (S1).
- Panels must be fully protected from water during unloading, storage and assembly; the straw must not be exposed to wetting in use (S1, S2).
- The DoP states that the straw shows a propensity to continuous smouldering under EN 16733 (S2); fire performance depends on the tested wall build-up.
- On-site or off-site pre-assembly is carried out by an independent builder, not by the producer (S1).
Technical Specifications
Values from the maker's documents listed at the end of this page. Check the current version with the maker before you specify.
Straw insulation (declared in the DoP under ETA-26/0071):
| Property | Value | Unit | Test standard | Source document |
|---|---|---|---|---|
| Thermal conductivity, λD (10, dry, 90/90) | 0.067 | W/(m·K) | EN 12667; EN ISO 10456; EAD 040146-00-1201 | S2 p2 |
| Reaction to fire | Class E | EN 13501-1 | S2 p1 | |
| Continuous smouldering | Shows propensity to undergo continuous smouldering (sample density 115 kg/m³) | EN 16733 | S2 p1 | |
| Bulk density of straw | 98 to 127 | kg/m³ | S2 p1 | |
| Water vapour diffusion resistance factor μ | 3.34 | EN 12086 | S2 p2 | |
| Hygroscopic sorption | 0.091 at 80% RH; 0.120 at 95% RH | kg/kg | EN ISO 12571:2022 | S2 p1 |
| Specific airflow resistivity | 6.03 | kPa·s/m² | EN ISO 9053-1 | S2 p1 |
| Assumed working life | 50 | years | per ETA-26/0071 | S2 p2 |
Panel (technical specification, 400 mm panel unless stated):
| Property | Value | Unit | Test standard | Source document |
|---|---|---|---|---|
| Fire resistance, panel | REI 45 (uncovered panel with exterior membrane: at least 45 minutes; full wall system up to 120 minutes) | not printed on this page | S1 p3, p4 | |
| Thermal resistance R | 6.558 | m²K/W | Passive House certified panel | S1 p4 |
| U-value | 0.152 | W/(m²K) | S1 p4 | |
| Thermal conductivity, panel | 0.0645 | W/(m·K) | S1 p4 | |
| Airborne sound insulation | Rw (C; Ctr) 30 (-1; -5) | dB | S1 p4 | |
| Phase shift | 18 | hours | S1 p4 | |
| Thickness | 300 to 400 | mm | S1 p4 | |
| Width (standard, braced, column, inclined) | 400 (424 column) to 850 | mm | S1 p4 | |
| Height | 400 to 3000 | mm | S1 p4 | |
| Manufacturing tolerance | ±2 per panel in all directions | mm | S1 p4 | |
| GWP-total, A1-A3 | -9.40E+1 per m² (400 mm panel) | kg CO2 eq. | EN 15804+A2 | S3 p31 |
| GWP-fossil, A1-A3 | 7.42E+0 per m² | kg CO2 eq. | EN 15804+A2 | S3 p31 |
| GWP-biogenic, A1-A3 | -1.01E+2 per m² | kg CO2 eq. | EN 15804+A2 | S3 p31 |
| GWP-total, C3 (end-of-life scenario in main table) | 1.02E+2 per m² | kg CO2 eq. | EN 15804+A2 | S3 p31 |
Reading note: the negative A1 to A3 GWP-total reflects biogenic carbon taken up by the straw and timber; the EPD shows that carbon released again in module C3 in its main end-of-life scenario. Read all modules together; A1 to A3 alone omits that release. Declared unit: 1 m² of an average panel, 400 mm thick, 60-year service life expectancy (S3, LCA information page 8).
Product Documents
| Document | Reference | Issued by | Status on 9 October 2026 | Link |
|---|---|---|---|---|
| European Technical Assessment | ETA-26/0071 of 13/04/2026, EAD 040146-00-1201 (straw bale thermal insulation) | TZÚS Prague (Technical Assessment Body) | Referenced in S1 and S2; the ETA document itself not opened | S2 |
| Declaration of Performance | Version 01/2026, AVCP system 3, dated 17.05.2026 | Manufacturer-issued | Opened. Note: it covers the straw insulation, not the panel's structural performance | S2 |
| EPD | EPD-IES-0033692:003, ISO 14025 and EN 15804:2012+A2:2019/AC:2021, version date 2026-09-25, valid to 2031-09-25 | Programme operator EPD International AB | EPD document opened (manufacturer-hosted copy) | S3 |
| FSC chain of custody | SGSCH-COC-210088, valid 23 April 2026 to 22 April 2031; FSC 100% and FSC Mix Credit under the transfer system | SGS | Certificate copy opened; FSC public register not opened | S4 |
| Passive House certified component | ID 0867cs03, cool temperate climate, valid until 31 December 2026 | Certificate copy opened; PHI database not opened | ||
| BBA, CodeMark | Not found |
About EcoCocon
- Company: EcoCocon s.r.o., Záhradnícka 60, 821 08 Bratislava, Slovak Republic; production at Industrial park Voderady (S2).
- Availability: shipped to EU countries, EEA member and cooperating countries, the USA and Canada; continental Europe, mainland UK and Ireland by enclosed lorry, other locations by container (S7). The transport guide refers to local partners for some destinations (S7).
- How to buy: project-based: price estimate from drawings, paid Panel Project, purchase agreement, production after advance payment, delivery after final payment (S6). Contact: https://ecococon.eu (contact routes on the site).
Sizes and Supply
| Item | Published |
|---|---|
| Ordering sequence and timing | Estimate about 1 week; Panel Project up to 8 weeks (separate, non-refundable fee); agreement up to 2 weeks; production up to 12 weeks after advance payment; delivery up to 2 weeks |
| Advance payment | 40% to 50% to start production |
| Lead time | Up to 12 weeks from order or contract signature to delivery |
| Packaging | Colour-coded, numbered packages of 6 to 12 panels (up to 1,000 kg); about 140 m² per curtainside lorry |
| Transport cost | Indicative per-lorry ranges by country are published by the manufacturer (EUR, excluding VAT); EcoGaboon links to the guide rather than repeating figures |
| Panel price, Panel Project fee | not published: not published; estimated per project from drawings |
Before You Specify
- The DoP covers the straw insulation (Class E, smouldering propensity); obtain the fire resistance classification report for the exact wall build-up and check national rules for the building height and use.
2.
- Structural design needs the manufacturer's structural engineering guide and project calculations; panel load tables depend on assumptions stated in the specification.
- Moisture protection during delivery, storage and assembly is a condition of the warranty and the DoP.
- Confirm the Passive House certificate renewal after 31 December 2026.
- For UK projects, confirm acceptance by the building control body and the warranty provider; no BBA certificate was found.
Similar Products
STEICOflex 036STEICO SE · Wood fibre battDeclared thermal conductivity, λD: 0.036 W/(m·K)Reaction to fire: Class E
Expanded Insulation Corkboard (ICB)Amorim Cork Solutions · Expanded cork boardThermal conductivity: 0.039 W/(m·K)Reaction to fire: Class E
Kerto LVL S-beam and Q-panelMetsä Wood · Laminated veneer lumber (softwood)Strength class, S-beam: LVL 48 P, thickness 21 to 90 mmDensity, mean / 5th percentile: 510 / 480 kg/m³
Source Documents
- S1: Technical specification v2.2 (04.06.2026)
- S2: Declaration of Performance for the straw insulation, under ETA-26/0071
- S3: EPD EPD-IES-0033692:003, International EPD System
- S4: FSC chain of custody certificate SGSCH-COC-210088 (copy on manufacturer site)
- S5: Passive House Institute certified component certificate 0867cs03 (copy on manufacturer site)
- S6: Order and Delivery Guide v2.0 (2026)
- S7: Indicative transport costs guide (2026-07-28)