Thermal conductivity, λD (10, dry, 90/90)
0.067 W/(m·K). Test standard: EN 12667; EN ISO 10456; EAD 040146-00-1201
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p2Explore straw wall panels through the listed products and the documents behind their declared properties. Product suitability and supply must be confirmed for the project.

Properties from the listed products' own documents. Check each one against your project.
0.067 W/(m·K). Test standard: EN 12667; EN ISO 10456; EAD 040146-00-1201
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p2Class E. Test standard: EN 13501-1
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p1Shows propensity to undergo continuous smouldering (sample density 115 kg/m³). Test standard: EN 16733
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p198 to 127 kg/m³
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p13.34. Test standard: EN 12086
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p20.091 at 80% RH; 0.120 at 95% RH kg/kg. Test standard: EN ISO 12571:2022
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p1Read the exact product and source before specifying.
2.
Where the makers say each product goes. The diagram shows the part of the building, not a construction detail.
As stated (S1):
Stated restrictions and conditions (S1, S2, S6):
Read each value together with its unit, standard and document. Values tested on different bases are not interchangeable.
| Product | Declared Values and Source | Next Step |
|---|---|---|
| EcoCocon Straw Panel | U-value, 400 mm panel: 0.152 W/(m²K) (technical specification v2.2 p4) Fire resistance, panel: REI 45 (technical specification p3, p4) Thermal conductivity of the straw, λD: 0.067 W/(m·K), EN 12667 (DoP under ETA-26/0071 p2) | Full Specification |
U-value, 400 mm panel: 0.152 W/(m²K) (technical specification v2.2 p4)
Fire resistance, panel: REI 45 (technical specification p3, p4)
The DoP covers the straw insulation, not the panel
About the MakerGuides connected to straw wall panels through their material topics.
No published guides are connected to this material yet.
See all straw wall panels guidesOnline requests are not open yet. Nothing you enter here is saved or sent.
Online enquiries are temporarily unavailable. No information has been saved or sent.
You can continue browsing the website and using its available tools. No enquiry, subscription, purchase or listing is submitted here.
We may use AI tools to help review documents under human supervision. Tell us before sending documents if you prefer otherwise. How We Use AI