Straw Wall Panels

Why Straw Wall Panels

Properties from the listed products' own documents. Check each one against your project.

Thermal conductivity, λD (10, dry, 90/90)

0.067 W/(m·K). Test standard: EN 12667; EN ISO 10456; EAD 040146-00-1201

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p2

Reaction to fire

Class E. Test standard: EN 13501-1

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p1

Continuous smouldering

Shows propensity to undergo continuous smouldering (sample density 115 kg/m³). Test standard: EN 16733

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p1

Bulk density of straw

98 to 127 kg/m³

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p1

Water vapour diffusion resistance factor μ

3.34. Test standard: EN 12086

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p2

Hygroscopic sorption

0.091 at 80% RH; 0.120 at 95% RH kg/kg. Test standard: EN ISO 12571:2022

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p1

Limitations and What to Check

Read the exact product and source before specifying.

EcoCocon Straw Panel

  • The DoP covers the straw insulation (Class E, smouldering propensity); obtain the fire resistance classification report for the exact wall build-up and check national rules for the building height and use.

2.

  • Structural design needs the manufacturer's structural engineering guide and project calculations; panel load tables depend on assumptions stated in the specification.
  • Moisture protection during delivery, storage and assembly is a condition of the warranty and the DoP.
  • Confirm the Passive House certificate renewal after 31 December 2026.
  • For UK projects, confirm acceptance by the building control body and the warranty provider; no BBA certificate was found.
Read the Product Page

Where It's Used

Where the makers say each product goes. The diagram shows the part of the building, not a construction detail.

123

EcoCocon Straw Panel

As stated (S1):

  • Load-bearing external walls in low-rise residential and non-residential buildings.
  • Façade infill or wrapping for skeleton-frame structures in mid-rise and high-rise buildings, including renovation wrapping.
  • Load-bearing partition walls.

Stated restrictions and conditions (S1, S2, S6):

  • Not for areas with permafrost (S1).
  • Panels must be fully protected from water during unloading, storage and assembly; the straw must not be exposed to wetting in use (S1, S2).
  • The DoP states that the straw shows a propensity to continuous smouldering under EN 16733 (S2); fire performance depends on the tested wall build-up.
  • On-site or off-site pre-assembly is carried out by an independent builder, not by the producer (S1).
1. Walls 2. Structure 3. Facades

Specification Details

Read each value together with its unit, standard and document. Values tested on different bases are not interchangeable.

ProductDeclared Values and SourceNext Step
EcoCocon Straw Panel

U-value, 400 mm panel: 0.152 W/(m²K) (technical specification v2.2 p4)

Fire resistance, panel: REI 45 (technical specification p3, p4)

Thermal conductivity of the straw, λD: 0.067 W/(m·K), EN 12667 (DoP under ETA-26/0071 p2)

Full Specification

Related Materials

Manufacturers

EcoCocon

EcoCocon Straw Panel

U-value, 400 mm panel: 0.152 W/(m²K) (technical specification v2.2 p4)

Fire resistance, panel: REI 45 (technical specification p3, p4)

  • dop: Linked (version 01/2026, straw insulation)
  • epd: Linked (EPD-IES-0033692:003, valid to 2031-09-25
  • certificate: Certificate copy (FSC SGSCH-COC-210088; Passive House 0867cs03 to 31 December 2026)
  • installationGuide: Not checked

The DoP covers the straw insulation, not the panel

About the Maker

Related Guides

Guides connected to straw wall panels through their material topics.

No published guides are connected to this material yet.

See all straw wall panels guides

Request Product Documents or Samples

Online requests are not open yet. Nothing you enter here is saved or sent.

Online Enquiries Are Not Open Yet

Online enquiries are temporarily unavailable. No information has been saved or sent.

You can continue browsing the website and using its available tools. No enquiry, subscription, purchase or listing is submitted here.

We may use AI tools to help review documents under human supervision. Tell us before sending documents if you prefer otherwise. How We Use AI

Submit a Project Requirement