Declared designation
ICB-EN 13170-L2-W2-T2-CS(10)100-TR50-WS-MU20-CC(0,8/0,4/10)5-AFr35. Test standard: EN 13170:2012
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p2Explore expanded cork insulation through the listed products and the documents behind their declared properties. Product suitability and supply must be confirmed for the project.

Properties from the listed products' own documents. Check each one against your project.
ICB-EN 13170-L2-W2-T2-CS(10)100-TR50-WS-MU20-CC(0,8/0,4/10)5-AFr35. Test standard: EN 13170:2012
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S2 p20.039 (0.040 declared for ACERMI certification) W/(m·K). Test standard: EN 12667
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S1 p1, p2; S2110 ± 10 kg/m³. Test standard: not stated
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S1 p1Class E. Test standard: EN 13501-1
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S1 p2; S2CS(10)100, at least 100 kPa. Test standard: EN 826
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S1 p2TR40, at least 40 (May 2026) vs TR50 (November 2024): versions disagree kPa. Test standard: EN 1607
For your project: Check this declared value against the exact product designation and the conditions in its source document.
S1 p2; S2 p2Read the exact product and source before specifying.
Where the makers say each product goes. The diagram shows the part of the building, not a construction detail.
Read each value together with its unit, standard and document. Values tested on different bases are not interchangeable.
| Product | Declared Values and Source | Next Step |
|---|---|---|
| Expanded Insulation Corkboard (ICB) | Thermal conductivity: 0.039 W/(m·K), EN 12667 (data sheets CTP-465/002 p1, p2 and CTP-465/001) Reaction to fire: Class E, EN 13501-1 (CTP-465/002 p2; CTP-465/001) Density: 110 ± 10 kg/m³ (CTP-465/002 p1) | Full Specification |
Thermal conductivity: 0.039 W/(m·K), EN 12667 (data sheets CTP-465/002 p1, p2 and CTP-465/001)
Reaction to fire: Class E, EN 13501-1 (CTP-465/002 p2; CTP-465/001)
Two data sheet versions disagree on other values; no DoP found
About the MakerGuides connected to expanded cork insulation through their material topics.
No published guides are connected to this material yet.
See all expanded cork insulation guidesOnline requests are not open yet. Nothing you enter here is saved or sent.
Online enquiries are temporarily unavailable. No information has been saved or sent.
You can continue browsing the website and using its available tools. No enquiry, subscription, purchase or listing is submitted here.
We may use AI tools to help review documents under human supervision. Tell us before sending documents if you prefer otherwise. How We Use AI