Skip to Content
EcoGaboonSource With Us

EcoCocon Straw Panel

EcoCocon · Timber frame with pressed straw

A load-bearing twin-stud timber frame panel filled with pressed straw at a homogeneous density, made to measure for each project (S1). Panels are assembled into walls and finished with further layers (for example a breather membrane, wood fibre board and clay plaster) to reach the required fire, thermal and acoustic performance (S1).

Where It Is Used

As stated (S1):

  • Load-bearing external walls in low-rise residential and non-residential buildings.
  • Façade infill or wrapping for skeleton-frame structures in mid-rise and high-rise buildings, including renovation wrapping.
  • Load-bearing partition walls.

Stated restrictions and conditions (S1, S2, S6):

  • Not for areas with permafrost (S1).
  • Panels must be fully protected from water during unloading, storage and assembly; the straw must not be exposed to wetting in use (S1, S2).
  • The DoP states that the straw shows a propensity to continuous smouldering under EN 16733 (S2); fire performance depends on the tested wall build-up.
  • On-site or off-site pre-assembly is carried out by an independent builder, not by the producer (S1).

Technical Specifications

Values from the maker's documents listed at the end of this page. Check the current version with the maker before you specify.

Straw insulation (declared in the DoP under ETA-26/0071):

PropertyValueUnitTest standardSource document
Thermal conductivity, λD (10, dry, 90/90)0.067W/(m·K)EN 12667; EN ISO 10456; EAD 040146-00-1201S2 p2
Reaction to fireClass EEN 13501-1S2 p1
Continuous smoulderingShows propensity to undergo continuous smouldering (sample density 115 kg/m³)EN 16733S2 p1
Bulk density of straw98 to 127kg/m³S2 p1
Water vapour diffusion resistance factor μ3.34EN 12086S2 p2
Hygroscopic sorption0.091 at 80% RH; 0.120 at 95% RHkg/kgEN ISO 12571:2022S2 p1
Specific airflow resistivity6.03kPa·s/m²EN ISO 9053-1S2 p1
Assumed working life50yearsper ETA-26/0071S2 p2

Panel (technical specification, 400 mm panel unless stated):

PropertyValueUnitTest standardSource document
Fire resistance, panelREI 45 (uncovered panel with exterior membrane: at least 45 minutes; full wall system up to 120 minutes)not printed on this pageS1 p3, p4
Thermal resistance R6.558m²K/WPassive House certified panelS1 p4
U-value0.152W/(m²K)S1 p4
Thermal conductivity, panel0.0645W/(m·K)S1 p4
Airborne sound insulationRw (C; Ctr) 30 (-1; -5)dBS1 p4
Phase shift18hoursS1 p4
Thickness300 to 400mmS1 p4
Width (standard, braced, column, inclined)400 (424 column) to 850mmS1 p4
Height400 to 3000mmS1 p4
Manufacturing tolerance±2 per panel in all directionsmmS1 p4
GWP-total, A1-A3-9.40E+1 per m² (400 mm panel)kg CO2 eq.EN 15804+A2S3 p31
GWP-fossil, A1-A37.42E+0 per m²kg CO2 eq.EN 15804+A2S3 p31
GWP-biogenic, A1-A3-1.01E+2 per m²kg CO2 eq.EN 15804+A2S3 p31
GWP-total, C3 (end-of-life scenario in main table)1.02E+2 per m²kg CO2 eq.EN 15804+A2S3 p31

Reading note: the negative A1 to A3 GWP-total reflects biogenic carbon taken up by the straw and timber; the EPD shows that carbon released again in module C3 in its main end-of-life scenario. Read all modules together; A1 to A3 alone omits that release. Declared unit: 1 m² of an average panel, 400 mm thick, 60-year service life expectancy (S3, LCA information page 8).

Product Documents

DocumentReferenceIssued byStatus on 9 October 2026Link
European Technical AssessmentETA-26/0071 of 13/04/2026, EAD 040146-00-1201 (straw bale thermal insulation)TZÚS Prague (Technical Assessment Body)Referenced in S1 and S2; the ETA document itself not openedS2
Declaration of PerformanceVersion 01/2026, AVCP system 3, dated 17.05.2026Manufacturer-issuedOpened. Note: it covers the straw insulation, not the panel's structural performanceS2
EPDEPD-IES-0033692:003, ISO 14025 and EN 15804:2012+A2:2019/AC:2021, version date 2026-09-25, valid to 2031-09-25Programme operator EPD International ABEPD document opened (manufacturer-hosted copy)S3
FSC chain of custodySGSCH-COC-210088, valid 23 April 2026 to 22 April 2031; FSC 100% and FSC Mix Credit under the transfer systemSGSCertificate copy opened; FSC public register not openedS4
Passive House certified componentID 0867cs03, cool temperate climate, valid until 31 December 2026Certificate copy opened; PHI database not opened
BBA, CodeMarkNot found

About EcoCocon

  • Company: EcoCocon s.r.o., Záhradnícka 60, 821 08 Bratislava, Slovak Republic; production at Industrial park Voderady (S2).
  • Availability: shipped to EU countries, EEA member and cooperating countries, the USA and Canada; continental Europe, mainland UK and Ireland by enclosed lorry, other locations by container (S7). The transport guide refers to local partners for some destinations (S7).
  • How to buy: project-based: price estimate from drawings, paid Panel Project, purchase agreement, production after advance payment, delivery after final payment (S6). Contact: https://ecococon.eu (contact routes on the site).

Sizes and Supply

ItemPublished
Ordering sequence and timingEstimate about 1 week; Panel Project up to 8 weeks (separate, non-refundable fee); agreement up to 2 weeks; production up to 12 weeks after advance payment; delivery up to 2 weeks
Advance payment40% to 50% to start production
Lead timeUp to 12 weeks from order or contract signature to delivery
PackagingColour-coded, numbered packages of 6 to 12 panels (up to 1,000 kg); about 140 m² per curtainside lorry
Transport costIndicative per-lorry ranges by country are published by the manufacturer (EUR, excluding VAT); EcoGaboon links to the guide rather than repeating figures
Panel price, Panel Project feenot published: not published; estimated per project from drawings

Before You Specify

  • The DoP covers the straw insulation (Class E, smouldering propensity); obtain the fire resistance classification report for the exact wall build-up and check national rules for the building height and use.

2.

  • Structural design needs the manufacturer's structural engineering guide and project calculations; panel load tables depend on assumptions stated in the specification.
  • Moisture protection during delivery, storage and assembly is a condition of the warranty and the DoP.
  • Confirm the Passive House certificate renewal after 31 December 2026.
  • For UK projects, confirm acceptance by the building control body and the warranty provider; no BBA certificate was found.