Kerto LVL S-beam and Q-panel

Metsä Wood · Laminated veneer lumber (softwood)

Laminated veneer lumber made from 3 mm rotary-peeled, strength-graded softwood veneers bonded with a phenol formaldehyde adhesive into a continuous billet, then sawn into beams, planks or panels (S3 p4). In the S-beam all veneers run in one direction; in the Q-panel some veneers are crosswise to give transverse strength and stiffness (S3 p4).

Where It Is Used

  • DoP intended use: buildings and bridges (S1, S2).
  • EPD: load-bearing and non-load-bearing structures such as beams, headers, studs, columns and panels for roof, wall and floor elements (S3 p5).
  • Product page: beams and headers, lintels, floor joists, rafters and ridge beams, truss chords, studs and columns, portal frames, element components, industrial components such as doors and windows, concrete formwork and scaffolding (S5).
  • Conditions of use: DoP values are for structural design to EN 1995 (Eurocode 5); in service class 2 the S-beam compression value fc,0,k of 35.0 N/mm² is recommended to be divided by 1.2 (S1 footnote).

Technical Specifications

Values from the maker's documents listed at the end of this page. Check the current version with the maker before you specify.

PropertyValueUnitTest standardSource document
Strength class, S-beamLVL 48 P, thickness 21 to 90 mmEN 14374:2004S1 p2
Strength class, Q-panelLVL 32 C (21 to 24 mm); LVL 36 C (27 to 75 mm)EN 14374:2004S2 p3
Modulus of elasticity, parallel to grainS-beam E0,mean 13800, E0,k 11600; Q-panel E0,mean 10000 (LVL 32 C) / 10500 (LVL 36 C)N/mm²EN 14374:2004S1 p2; S2 p3
Bending strength fm,0,edge,k (depth 300 mm)S-beam 44.0; Q-panel 28.0 (LVL 32 C) / 32.0 (LVL 36 C)N/mm²EN 14374:2004S1 p2; S2 p3
Compression fc,0,k, S-beam35.0 (divide by 1.2 in service class 2, as recommended)N/mm²EN 14374:2004S1 p2
Tension ft,0,k (length 3000 mm), S-beam35.0N/mm²EN 14374:2004S1 p2
Shear fv,0,edge,k, S-beam4.2N/mm²EN 14374:2004S1 p2
Density, mean / 5th percentile (S-beam and Q-panel)510 / 480kg/m³EN 14374:2004S1 p2; S2 p3
Reaction to fire, any substrate or air gap, min 21 mmD-s2, d0 (floorings Dfl-s1)EuroclassEN 14374 (DoP)S1 p3; S2 p4
Reaction to fire, min 27 mm, stated end-use conditionsD-s1, d0EuroclassEN 14374 (DoP)S1 p3; S2 p4
Formaldehyde releaseE1 (DoP); approx. 0.018 ppm, equal to 0.022 mg/m³ (EPD)class / ppmEN 717-1 (EPD)S1; S2; S3 p6
Durability against biological attackDurability class 5 (includes sapwood)classEN 350-2S1; S2
Thermal conductivitynot published
GWP-total, A1-A3-6.72E+02 per 1 m³ Kerto LVLkg CO2 eq.EN 15804+A2S3 p11
GWP-fossil, A1-A31.19E+02 per 1 m³kg CO2 eq.EN 15804+A2S3 p11
GWP-biogenic, A1-A3-7.91E+02 per 1 m³kg CO2 eq.EN 15804+A2S3 p11

Reading note: the declared unit is 1 m³ of Kerto LVL at 500 kg/m³, an average across several Kerto products, with 2024 data from the Lohja and Punkaharju mills (S3 p5, p6). The negative A1 to A3 GWP-total comes from the biogenic carbon term (-7.91E+02 kg CO2 eq. per m³); the EPD main results table shows GWP-total in module C3 of about 8.71E+02 kg CO2 eq. per m³, which is that carbon released at end of life (S3 p11; the cached text extraction of this table is partly garbled, so confirm against the PDF). Read all modules together; A1 to A3 alone omits that release. The EPD mass of 500 kg/m³ differs from the DoP mean density of 510 kg/m³ (S1, S3); the EPD figure is an average across products.

Product Documents

DocumentReferenceIssued byStatus on 9 October 2026Link
Declaration of Performance, S-beamMW/LVL/311-001/CPR/DOP, signed Espoo 10.7.2023; AVCP system 1; EN 14374:2004; notified body Eurofins Expert Services Oy No. 0809, certificate of constancy of performance 0809-CPR-1002Manufacturer-issued (notified body certification under system 1)OpenedS1
Declaration of Performance, Q-panelMW/LVL/312-001/CPR/DOP, signed Espoo 10.7.2023; same notified body and certificateManufacturer-issuedOpenedS2
Earlier DoP, S-beamVersion dated 19.12.2019Manufacturer-issuedOpened; S-beam values identical where compared; superseded by S1S6
EPDEPD-IES-0026805:001; ISO 14025 and EN 15804:2012+A2:2019/AC:2021; PCR 2019:14 v2.0.1 with c-PCR-006 v1.0.0; version date 2026-02-15, valid until 2031-02-15; EPD of multiple products (average)Programme operator EPD International AB; independent third-party verifierEPD document opened (manufacturer-hosted copy); Environdec. An older registration S-P-02802 appears in search results, not openedS3
Certificates and approvals sheetLists CE and UKCA marking; Eurofins product certificate EUFI29-20000676-C; Germany Z-9.1-847 and Z-9.1-291; Norway SINTEF TG 2142; USA ICC-ES ESR-3633 (S-beam) and ESR-4831 (Q-panel); Canada ESL-1606 and ESL-1605; Japan JAS JPIC-LV27; M1 emission classification; BM TRADA Q-Mark for door coresManufacturer-issued summary of third-party approvalsSheet opened; none of the listed approvals opened at the issuing body. The file name reads 052023 but the footer reads 08/2025
PEFC and FSC chain of custodyPEFC logo licence PEFC/02-31-381; FSC licence code FSC-C209093 (Lohja and Punkaharju mills)Certification bodiesStated in S3 p3 and S4; PEFC and FSC registers not opened
ETANot applicable (harmonised standard EN 14374 applies)
BBA, CodeMark, KOMONot found

About Metsä Wood

  • Company: Metsäliitto Cooperative, trading as Metsä Wood, part of Metsä Group; head office Revontulenpuisto 2, 02100 Espoo, Finland (S3 p3); DoP address P.O. Box 24, FI-08101 Lohja (S1).
  • Production: Kerto LVL mills at Lohja, Punkaharju and Äänekoski, Finland; Äänekoski was in construction during the EPD data year (S3 p5).
  • Availability: CE and UKCA marked, with national approvals in the USA, Norway, Canada, Germany and Japan (S4). Metsä Wood UK operates manufacturing and distribution sites at King's Lynn and Boston; the King's Lynn page does not say Kerto LVL is stocked there (S7).
  • How to buy: the product page refers to a global sales network contact search; no named distributors (S5). Contact: https://www.metsagroup.com/metsawood/contacts/.

Sizes and Supply

ItemPublished
Thickness range, S-beam21 to 90 mm
Thickness range, Q-panel21 to 75 mm, with lay-ups listed
Widths, lengths, pack sizes, MOQ, lead time, pricenot published

Before You Specify

  • Reaction to fire is D-s2, d0 (minimum 21 mm) or D-s1, d0 (minimum 27 mm, stated end-use conditions) only; check national rules for the building height, use and location of exposed timber.
  • Apply the recommended reduction of fc,0,k (divide by 1.2) in service class 2, and design to EN 1995 with the values in the current DoP.
  • Confirm the current DoP version in the Metsä Wood DoP library; two S-beam versions (2019 and 2023) are online.

4.

  • Confirm it is the current registration rather than S-P-02802.
  • The EPD is an average of several Kerto products; confirm it is accepted for the specific product in a project carbon assessment.
  • Thermal conductivity was not found in any document opened.
  • UK and Australian stocking routes, and any Australian certification, are not confirmed.
  • The certificates sheet file name (052023) and footer (08/2025) differ; obtain the current sheet.