Why Reconstituted Slate

Properties from the listed products' own documents. Check each one against your project.

Size (overall)

330 x 336 mm

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Linear cover of one slate

300 mm

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Minimum pitch and headlap

15° at 75 mm; 25° at 50 mm. Test standard: BS 5534 design basis

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Maximum pitch

90 (subject to fixing specification) °

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Headlap range

50 to 90 mm

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Batten gauge

minimum 210; maximum 225 below 25°, 250 at 25° and over mm

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1

Limitations and What to Check

Read the exact product and source before specifying.

Redland Cambrian Interlocking Slate

  • Confirm the current BBA issue and scope on the BBA register; the copy opened is from 2020.
  • For wall cladding, check current building regulations on combustible materials in external walls; the product has no declared Euroclass in the 2020 certificate.
  • Obtain a BS 5534 fixing specification for the site's wind exposure (the data sheet refers to the manufacturer's fixing calculation tool).
  • Ask for the recycled slate share and any EPD if the project needs them; neither is published in the documents opened.
  • Use the system accessories listed by the manufacturer; the certificate covers the supplied nails and clips only.
Read the Product Page

Where It's Used

Where the makers say each product goes. The diagram shows the part of the building, not a construction detail.

12

Redland Cambrian Interlocking Slate

As stated (S1, S2):

  • Pitched timber roofs with a rafter pitch of 15° or more (75 mm headlap at 15°; 50 mm at 25°), up to 90° subject to fixing specification.
  • Vertical cladding on the outer face of external walls.

Stated restrictions (S2, 2020 certificate):

  • Roof use is unrestricted for external fire spread (EXT.S.AA to BS 476-3).
  • As wall cladding the certificate gives a Class 2 surface (BS 476-6 and BS 476-7) and limits use in England, Wales and Northern Ireland to walls less than 18 m above ground and 1 m or more from the relevant boundary; in Scotland, to buildings with no storey more than 11 m above ground and more than 1 m from the boundary.
  • The certificate holder had not declared a reaction to fire class to BS EN 13501-1. Building regulations on combustible materials in external walls have changed since 2020: check current requirements before any wall use.
  • Minimum pitch assumes a maximum rafter length of 10 m; longer rafters need technical advice (S1).
  • The certificate warns of reduced life in areas of high alkali pollution (S2).
1. Roofs 2. Facades

Specification Details

Read each value together with its unit, standard and document. Values tested on different bases are not interchangeable.

ProductDeclared Values and SourceNext Step
Redland Cambrian Interlocking Slate

Minimum pitch and headlap: 15° at 75 mm; 25° at 50 mm, BS 5534 design basis (technical data sheet RED_TDS_2203)

Weight on roof: 18 kg/m² at 225 mm gauge; 17 kg/m² at 250 mm gauge (RED_TDS_2203)

Covering capacity: 14.8 slates/m² at 225 mm gauge; 13.3 at 250 mm gauge (RED_TDS_2203)

Full Specification

Related Materials

Manufacturers

BMI Redland

Redland Cambrian Interlocking Slate

Minimum pitch and headlap: 15° at 75 mm; 25° at 50 mm, BS 5534 design basis (technical data sheet RED_TDS_2203)

Weight on roof: 18 kg/m² at 225 mm gauge; 17 kg/m² at 250 mm gauge (RED_TDS_2203)

  • dop: On request (not located)
  • epd: Not published (none found)
  • certificate: Certificate copy (BBA 87/1907, 2020 issue; register not opened)
  • installationGuide: Not checked

Certificate copy opened is the 2020 BBA issue; current issue to check

About the Maker

Related Guides

Guides connected to reconstituted slate through their material topics.

No published guides are connected to this material yet.

See all reconstituted slate guides

Request Product Documents or Samples

Online requests are not open yet. Nothing you enter here is saved or sent.

Online Enquiries Are Not Open Yet

Online enquiries are temporarily unavailable. No information has been saved or sent.

You can continue browsing the website and using its available tools. No enquiry, subscription, purchase or listing is submitted here.

We may use AI tools to help review documents under human supervision. Tell us before sending documents if you prefer otherwise. How We Use AI

Submit a Project Requirement