Skip to Content
EcoGaboonSource With Us

Engineered and Modified Timber

Explore engineered and modified timber through the listed products and the documents behind their declared properties. Product suitability and supply must be confirmed for the project.

Products
4
Manufacturers
4
Last Checked
9 October 2026
Request Product Documents or Samples

Why Engineered and Modified Timber

Properties from the listed products' own documents. Check each one against your project.

Strength class, S-beam

LVL 48 P, thickness 21 to 90 mm. Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1 p2

Strength class, Q-panel

LVL 32 C (21 to 24 mm); LVL 36 C (27 to 75 mm). Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S2 p3

Modulus of elasticity, parallel to grain

S-beam E0,mean 13800, E0,k 11600; Q-panel E0,mean 10000 (LVL 32 C) / 10500 (LVL 36 C) N/mm². Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1 p2; S2 p3

Bending strength fm,0,edge,k (depth 300 mm)

S-beam 44.0; Q-panel 28.0 (LVL 32 C) / 32.0 (LVL 36 C) N/mm². Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1 p2; S2 p3

Compression fc,0,k, S-beam

35.0 (divide by 1.2 in service class 2, as recommended) N/mm². Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1 p2

Tension ft,0,k (length 3000 mm), S-beam

35.0 N/mm². Test standard: EN 14374:2004

For your project: Check this declared value against the exact product designation and the conditions in its source document.

S1 p2

Limitations and What to Check

Read the exact product and source before specifying.

Kerto LVL S-beam and Q-panel

  • Reaction to fire is D-s2, d0 (minimum 21 mm) or D-s1, d0 (minimum 27 mm, stated end-use conditions) only; check national rules for the building height, use and location of exposed timber.
  • Apply the recommended reduction of fc,0,k (divide by 1.2) in service class 2, and design to EN 1995 with the values in the current DoP.
  • Confirm the current DoP version in the Metsä Wood DoP library; two S-beam versions (2019 and 2023) are online.

4.

  • Confirm it is the current registration rather than S-P-02802.
  • The EPD is an average of several Kerto products; confirm it is accepted for the specific product in a project carbon assessment.
  • Thermal conductivity was not found in any document opened.
  • UK and Australian stocking routes, and any Australian certification, are not confirmed.
  • The certificates sheet file name (052023) and footer (08/2025) differ; obtain the current sheet.
Read the Product Page

SterlingOSB Zero OSB3

  • Obtain the current EPD before any carbon assessment.
  • Reaction to fire is D-s2, d0 at best (minimum 9 mm, no air gap); the BBA certificate states the board does not achieve C-s2, d3 or better and its use is restricted in some cases. Check national rules for the building height and use.
  • OSB/3 is for humid conditions in biological use classes 1 and 2; it is not for exterior exposure without protection.
  • Check BBA certificate 01/3857 validity and scope on the BBA website.
  • Confirm that the Inverness DoP v13 is the one supplied with SterlingOSB Zero, since the brand name is not on the DoP; for UK projects obtain the UKCA DoP.
  • Do not use Genk (Belgium) OSB/3 documents for this product.
  • The DoP does not state density; the BBA certificate gives a mean density of not more than 600 kg/m³ for the 9 and 11 mm sheathing grades.
  • The site is Inverness for OSB; Cowie appears in West Fraser documents for other products and as the FSC certificate holder address.
Read the Product Page

Glued laminated timber (GLT)

  • The DoP (2022) is held by HASSLACHER Holzbausysteme GmbH, while the EPD covers NORITEC Holzindustrie GmbH production at Sachsenburg; confirm which entity and plant supply the order and obtain the matching DoP.
  • Several EPD numbers are in circulation (2021, 2025 and 2026); check the current one in the IBU register.
  • Reaction to fire is D-s2, d0; resistance to fire is NPD in the DoP and depends on the member design. Check national rules for the building height and use.
  • Glued solid timber is limited to service classes 1 and 2; glulam is stated for service classes 1 to 3.
  • Supply is to commercial customers only.

6.

  • Confirm the adhesive system (DoP: MUF; brochure: melamine resin).
Read the Product Page

Accoya wood

  • Obtain the current Accsys data sheet and Wood Information Guide; the copy opened is dated 2020.
  • Reaction to fire is Euroclass D untreated; check the façade fire requirements for the building and jurisdiction, and the classification of any fire-treated version.
  • Confirm FSC chain of custody for the supply chain (manufacturer, distributor and processor) if certified timber is specified.
  • If an EPD is needed, confirm which EPD matches the actual product supplied (the opened register entry is owned by one distributor).
  • Follow the fixing and adhesive guidance; mild steel fixings are not recommended.
Read the Product Page

Where It's Used

Where the makers say each product goes. The diagram shows the part of the building, not a construction detail.

12345

Accoya wood

From the data sheet (S1):

  • Cladding, decking, windows, doors and other exterior joinery made by processors from sawn stock; the manufacturer runs a training programme for companies making Accoya products and recommends that they take part.
  • Ground contact and salt water contact are discussed with field test results; the data sheet reports some marine organism attack in long immersion tests.

Stated conditions (S1):

  • Use corrosion-proof stainless steel fixings (A2 or A4 to EN 10088-1).
  • Adhesives: PU, EPI, epoxy and PRF give the best results; PVAc results vary; MUF should be avoided.
  • Fire: Euroclass D like most softwoods; fire treatment is needed to meet higher requirements.
5. Facades

Glued laminated timber (GLT)

  • DoP intended use: buildings and bridges (S1).
  • EPD: all structural areas of timber construction, including bridge building; service classes 1 to 3 to EN 1995-1-1, with glued solid timber limited to service classes 1 and 2 (S2 p3).
  • Product page: houses and apartment buildings, multi-storey residential and office buildings, public buildings, agricultural buildings, industrial and production halls, sports and leisure halls; roof structures, long-span beams, columns and ceiling structures (S4).
  • Stated restriction: preventive chemical wood preservation is described as unusual and only permissible in limited cases (S2 p3).
1. Structure 3. Roofs

Kerto LVL S-beam and Q-panel

  • DoP intended use: buildings and bridges (S1, S2).
  • EPD: load-bearing and non-load-bearing structures such as beams, headers, studs, columns and panels for roof, wall and floor elements (S3 p5).
  • Product page: beams and headers, lintels, floor joists, rafters and ridge beams, truss chords, studs and columns, portal frames, element components, industrial components such as doors and windows, concrete formwork and scaffolding (S5).
  • Conditions of use: DoP values are for structural design to EN 1995 (Eurocode 5); in service class 2 the S-beam compression value fc,0,k of 35.0 N/mm² is recommended to be divided by 1.2 (S1 footnote).
1. Structure 2. Walls 3. Roofs

SterlingOSB Zero OSB3

  • DoP intended use: internal and external use as structural components in humid conditions; biological use classes 1 and 2 (S1).
  • Product page: flat and pitched roofs (including GRP roofing), wall sheathing, timber frame, flooring, sheds, portable buildings, caravans, agricultural buildings, hoardings, exhibition displays, built-in furniture, shelving, packaging, pallets, DIY and interior decorative use (S2).
  • BBA Product Sheet 6: loadbearing sheathing on timber-frame walls of domestic and non-domestic buildings (S5).
  • Stated restriction: the board does not achieve a reaction to fire classification of C-s2, d3 or better, and its use is restricted in some cases (S5 section 7).
1. Structure 2. Walls 3. Roofs 4. Flooring

Specification Details

Read each value together with its unit, standard and document. Values tested on different bases are not interchangeable.

ProductDeclared Values and SourceNext Step
Accoya wood

Durability: Class 1, EN 350 (data sheet, 2020, p2)

Density: average 510 kg/m³ (range 400 to 600) at 65% RH, 20 °C (data sheet p2)

Reaction to fire: D (Europe) (data sheet p2)

Full Specification
Glued laminated timber (GLT)

Reaction to fire: D-s2, d0 (DoP DOP_HHS_BSH p3; brochure p5)

Standard heights: 80 to 1,280 mm in 40 mm steps (brochure p4)

Lengths: up to 27 m; up to 42 m as special components (brochure p4)

Full Specification
Kerto LVL S-beam and Q-panel

Strength class, S-beam: LVL 48 P, thickness 21 to 90 mm, EN 14374:2004 (DoP MW/LVL/311-001 p2)

Density, mean / 5th percentile: 510 / 480 kg/m³ (DoP S-beam p2; DoP Q-panel p3)

Reaction to fire, min 21 mm: D-s2, d0 (DoP S-beam p3; DoP Q-panel p4)

Full Specification
SterlingOSB Zero OSB3

Product type and thickness range: OSB/3, over 6 mm to 32 mm, EN 13986:2004+A1:2015 (DoP WFOSB3DoPv13 p1)

Reaction to fire, min 9 mm, no air gap behind: D-s2, d0 (DoP p2)

Formaldehyde release: E0.5 (DoP p2)

Full Specification

Related Materials

Manufacturers

Accsys Technologies

Accoya wood

Durability: Class 1, EN 350 (data sheet, 2020, p2)

Density: average 510 kg/m³ (range 400 to 600) at 65% RH, 20 °C (data sheet p2)

  • dop: Not published (not found)
  • epd: Distributor's only (EPD for a distributor's cladding product, register-confirmed; not an Accsys EPD)
  • certificate: Not checked
  • installationGuide: Not checked

Data sheet dated 2020, distributor-hosted copy

About the Maker

HASSLACHER NORICA TIMBER

Glued laminated timber (GLT)

Reaction to fire: D-s2, d0 (DoP DOP_HHS_BSH p3; brochure p5)

Standard heights: 80 to 1,280 mm in 40 mm steps (brochure p4)

  • dop: Linked (DOP_HHS_BSH)
  • epd: Linked (EPD-HAS-20260506-IBC1-EN, valid to 10.08.2031
  • certificate: Not checked
  • installationGuide: Not checked

Supply to commercial customers only

About the Maker

Metsä Wood

Kerto LVL S-beam and Q-panel

Strength class, S-beam: LVL 48 P, thickness 21 to 90 mm, EN 14374:2004 (DoP MW/LVL/311-001 p2)

Density, mean / 5th percentile: 510 / 480 kg/m³ (DoP S-beam p2; DoP Q-panel p3)

  • dop: Linked (MW/LVL/311-001 and 312-001)
  • epd: Linked (EPD-IES-0026805:001, valid to 2031-02-15
  • certificate: Not checked (approvals listed, not opened)
  • installationGuide: Not checked
About the Maker

West Fraser Europe

SterlingOSB Zero OSB3

Product type and thickness range: OSB/3, over 6 mm to 32 mm, EN 13986:2004+A1:2015 (DoP WFOSB3DoPv13 p1)

Reaction to fire, min 9 mm, no air gap behind: D-s2, d0 (DoP p2)

  • dop: Linked (WFOSB3DoPv13; brand name not printed on it)
  • epd: Expired version only (2020 EPD expired 30 January 2025; current not opened)
  • certificate: Certificate copy (BBA 01/3857 PS6, FSC SA-COC-008109; registers not opened)
  • installationGuide: Not checked

Current EPD not opened; 2020 EPD expired

About the Maker

Related Guides

Guides connected to engineered and modified timber through their material topics.

No published guides are connected to this material yet.

See all engineered and modified timber guides

Request Product Documents or Samples

Online requests are not open yet. Nothing you enter here is saved or sent.

Online Enquiries Are Not Open Yet

Online enquiries are temporarily unavailable. No information has been saved or sent.

You can continue browsing the website and using its available tools. No enquiry, subscription, purchase or listing is submitted here.

We may use AI tools to help review documents under human supervision. Tell us before sending documents if you prefer otherwise. How We Use AI

Submit a Project Requirement